26 October 2009 K2 Storage Area Network Installation and Service Manual 260
Configuring RAID
The Bind dialog box opens showing all unbound disks for the controller listed
in the Available Disk list.
b. Leave Full Bind unchecked. Refer to “About full/background bind” on
page 455.
c. In the
Bind Type drop down box, select RAID 5 or RAID 6, as specified by your
system design.
d. In the Available Disks box, select six contiguous disks at the top of the list. (TIP:
Use ‘shift-click’ or ‘control-click’ to select disks.).
e. Click the add (arrow) button to add disks to the Selected Disks list.
NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click
Identify Disks. This causes the disk drive light to flash.
f. Click
OK to close the Bind dialog box and begin the binding process. The
Progress Report dialog box opens, showing the status of the binding process.